Rosemount Vortex Flowmeter 8800DF030SD1N1D1E5M5
The Rosemount 8800 Series Vortex Flowmeter features a gasket-free, non-clogging flowmeter body that eliminates potential leak points for maximum process availability and less unplanned shutdown for world-class reliability. The unique design of the Emerson Rosemount 8800 Vortex Flowmeter uses an isolated sensor that eliminates the need to disassemble process and seals for flow and temperature sensor replacement.
Product specifications
Download full specification
Flowmeter Accuracy ±0.65% of liquid volume rate when using the MultiVariable option
±1% of gas and vapor volume rate
±0.70% of the mass flow of water when using the MultiVariable option
±2% steam mass flow
Rejected 38:1
Production 4 to 20 mA, HART? 5 or 7
4 to 20 mA, HART? 5 or 7 and expandable pulse output
Foundation; Fieldbus ITK6 with 2 analog input blocks, 1 Backup Link Active Scheduler function block and 1 integral function block (1 PID function block optional)
Wetted material stainless steel - 316 / 316L and CF3M
Nickel alloys - C-22 and CW2M
High temperature carbon steel - A105 and WCB
Low temperature carbon steel - LF2 and LCC
Duplex UNS S32760 and 6A
Consult factory for other wetted material options
Flange Options ANSI Class 150 to 1500
DIN PN 10 to PN 160
JIS 10K to 40K
Flanges provide a variety of surfaces
Please consult the factory for additional flange ratings
Operating temperature -330°F to 842°F (-200°C to 450°C)
Line size Flange: ? inches to 12 inches (15 to 300 mm)
Wafer: ? inches to 8 inches (15 to 200 mm)
Double: ? inches to 12 inches (15 to 300 mm)
Reducer: 1" to 14" (25 to 350 mm)
feature
Unique isolation sensor design allows for replacement without damaging the process seal
No gasket flow meter, no moving parts, increasing plant availability and reducing potential leaks
Eliminates downtime and maintenance costs associated with blocked pulse lines with a non-clogging flowmeter body design
Anti-vibration through adaptive digital signal processing with mass balance sensor and visual filtering
Each instrument includes a standard internal signal generator that simplifies electronic device verification
All instruments are pre-configured and hydrostatic tested to make them ready and easy to install
Simplify SIS standards with available dual vortex flowmeters and four-flow vortex flowmeters
Detection of liquid to gas phase transitions using Smart Fluid Diagnostics
8800D vortex flowmeter
F flange type
030 3 inches (80 mm)
S 316L forged stainless steel and CF-3M cast stainless steel
D1 DIN PN16 (PN 10/16 suitable for clamping type) 2526-D type
N Standard: -40-450 °F (-40-232 ° C)
1 1/2-14NPT-aluminum housing
D 4-20mA digital electronic components (Hart protocol)
1 actual flow calibration
E5 FM explosion-proof certification Dust--detonation
M5 LCD indicator