Micro Chromatograph

Zhejiang Finetec Instruments Co., Ltd

Product Description

  • Brand Name: Finetec
  • Electronic Mode
    Plug and play controller, furnace and detector
    Input and GC storage by touch screen
    Displaying all the actual and setting value of GC parameter
    Clients’ parameter setting has protection function for permission
    Furnace temperature controlled program has multiple kinds of gradient for selections
    Carrier gas controlled program has multiple grades
    Switch control of relay and solenoid valve of time order
    All the parameters for detectable probe displaying in single screen
    Two electric pressure controllers
    Atmospheric pressure and temperature compensation
    EPC controlled resolution ratio reaches 0.1Kpa
    Micro processer control
    Patent digital signal treating
    Universal voltage input: 220VAC, filtering and changing via linear
    Source: 336W(48VDC ×7AMPS)
    DC electrical source available
     
    Basic Features:
    Plug and play module design
    Multiple standards application specific profiles
    Colorful touch screen controlled design
    Continuous operation by internal GC
    Patent digital signal process
    Internaldiagnostic program
    Electric pressure controller precision: 0.001KPaf
    Furnace resists 325℃ environmental temperature
    Temperature gradient of furnace is 80℃/min, heating speed reaches to 80℃/min in maximum, moment heating ratio can reach 25℃/sec, temperature controlled precision is ±0.001°C
    Fast cooling (325 to 50℃). ≤4 min,
    Compact and light design
    Water resistant briefcase size(52×40×21cm)
    Weight: about 10kg
    One or two compact gas cylinder (purchase independently available)
     
    Detector:
    Accuracy: < 10%, precision: 5% RSD
    Both independent and combined installations are available
    0.1℃ resolution ratio, maximum temperature is 300℃
    Realize 24 digit output via USD port
    EPC pressure controlled precision: 0.1KPa
    Available Detector:
    FID-------flame ionization detector (100×10-9g limit)
    PID-------photo ionization detector (10×10-9g limit)
    TCD------thermal conductivity detector (1×10-6g limit)
    HID-------hydrogen ionization detector (100×10-9g limit)
    NPD------ nitrogen-phosphorus detector (20×10-9g limit)
    TID--------thermal detector (20×10-9g limit)
    ECD-------electron capture detector (0.1×10-9g limit)
     
    Furnace Module:
    Temperature resistant up to 325℃ column temperature
    Temperature gradient of the furnace 80℃/min
    Fast cooling (325 to 50℃), ≤4 min,
    200W heating element
    Multiple temperature gradient set, precision is 0.1℃
    Appearance size: 12.5×10.5×12.5cm
    Single electron sample valve is available
    Source: car inventor (convertor equipped), external handled rechargeable battery

     
    Sample Injector:
    One or two optional installation
    Shunt or nun-shunt calibration, gas sample needn’t heat
    Circular injection tube cooling
    Multiple gradient set, precision is 0.1KPa
    Equipped with two control solenoid
    Digital communication:
    Two-way connection general data system
    USB digital signal output
    Network connection
    GC of operating Windows XP works in enterprise net compatible network
    The computer of ETX structure can be used in the GC control and data read
    Applying the web of Windows network protocol for web connection
    LAN/WAN/VPN remote controlled GC data read

Company Profile

  • zhejiang Finetec Instruments Co., Ltd
  • [ China ]
  • This company is registered as a free member and is not verified or authenticated by Tradekey.com
  • COMPANY PROFILE The FINETEC INSTRUMENT COMPANY located in the Zhejiang province China 2012 High end micro pore surface and porosity analyzer approved by the market Pilot plant test laboratory is approved in the catalyst and chemical synthesis area The analyzer CBM and shale gas fill the domestic blank High end experimental furnace, vacuum oven and multidigit sample valve are launched. ...

Basic Information

  • Company Products / Services: instruments gas chromatograph chemical analyzer
  • Year Established: 2007
  • Number of Employees: 26-50
  • Website: www.finetec.info
Contact Now