Solar Pv Module Wet Leakage Current Tester

Dongguan Hong Tu Instrument Co., Ltd

Product Description

  • Brand Name: HOTOTECH
  • Power: Hydraulic
  • 1. Measuring the insulation operation under the wet conditions, checking the part of internal circuit component

    That can't access to rain, fog, dew or snow melt moisture, It may cause corrosion, leakage or accidents if the part access to the moisture

    2. According to IEC 61215-2005, UL 1703-2004

    Apparatus


    1. Shallow sink

    Inner dimension 2600× 2200mm

    Material: PVC Insulation

    2. The room should be big enough that the solution inside submerge the whole module

    A. Resistivity not exceeding 3500Ω Cm

    B. Surface tension not exceed 0.03N M-1

    C. Temperature: 22° C± 3° C

    The solution should deep enough, not include lead box entrance

    3. Sprinklers with the same solution

    4.500V available current limit with DC power

    5. Equipment that for measuring the insulation resistance

    Procedure

    A. Inlet leads should be sprayed wholly by the solution, if the module connect to plug-in connector, plug- in Should be soaked in the solution during testing

    B. The speed that not exceed 500V S-1 increase the voltage until 500V, should be kept 2 min, then test the insulation resistance

    C. Reduce the voltage to zero, made the short-circuit of test equipment leading-out Terminal, for releasing voltage from internal module

    Solar PV Module Wet Leakage Current Tester

    1. Measuring the insulation operation under the wet conditions, checking the part of internal circuit component

    That can't access to rain, fog, dew or snow melt moisture, It may cause corrosion, leakage or accidents if the part access to the moisture

    2. According to IEC 61215-2005, UL 1703-2004

    Apparatus

    1. Shallow sink

    Inner dimension 2600× 2200mm

    Material: PVC Insulation

    2. The room should be big enough that the solution inside submerge the whole module

    A. Resistivity not exceeding 3500Ω Cm

    B. Surface tension not exceed 0.03N M-1

    C. Temperature: 22° C± 3° C

    The solution should deep enough, not include lead box entrance

    3. Sprinklers with the same solution

    4.500V available current limit with DC power

    5. Equipment that for measuring the insulation resistance

    Procedure

    A. Inlet leads should be sprayed wholly by the solution, if the module connect to plug-in connector, plug- in

    Should be soaked in the solution during testing

    B. The speed that not exceed 500V S-1 increase the voltage until 500V, should be kept 2 min, then test the insulation resistance

    C. Reduce the voltage to zero, made the short-circuit of test equipment leading-out Terminal, for releasing voltage from internal module




     

Company Profile

  • Dongguan Hong Tu Instrument Co., Ltd
  • [ China ]
  • This company is registered as a free member and is not verified or authenticated by Tradekey.com
  • Dongguan Hong Tu Instrument Information co.,ltd specializes in developing and producing helmet impact testing machines.We have firm connections and full cooperation from China's National Third-party Quality inspection and Notarization Center on producing and developing high-precision testing machines according to ECE, EN, DOT, SNELL, GB, AS, JIS and other standards. We are the largest helmet te...

Basic Information

  • Company Products / Services: helmet test machine, pv module testing machine
  • Year Established: 2006
  • Number of Employees: 26-50
  • Website: http://www.htinstrument.cn
Contact Now