Rpc-c X-ray Pipeline Crawler

Liaoning Ruiland Science & Technology Co., Ltd

Product Description

  • Brand Name: RST
  • lThe magnetic locators control,  positioning accuracy is ± 5mm;

    lSmall size, easy operation, modular structure design;

    lThe whole vehicle adopts high-quality stainless steel and advanced;

    lMultiple protective function: over voltage, overheat detection, under-mA and other protection functions;

    lThe cause of the fault is displayed on the touch screen for users identification and maintenance;

    lThe machine can be specially made according to users special needs, keeping qualified performance.

     

    1.Diameter range of suitable pipelineΦ273mm—Φ710mm
     
    2.Maximum penetration thicknessA3 stainless steel, 24mm
     
    3.Maximum output voltageFrom 150 to 200KV continuous adjustable
     
    4.Maximum output current3mA
     
    5.Focal spot1.0×2.0mm, 360°×30°
     
    6.Ambient temperature and humid limits-40°~ 70°, ≤90%
     
    7.Battery energylead-acid battery (9 pieces):110V, 10Ah
     
    8.Switzerland Motor power150W
     
    9.Exposure safety delay24s
     
    10.Exposure timer1~300 secondspreset
     
    11.Max gradient(simple vehicle-clean pipe)27°
     
    12.Positioning accuracy ±5mm
     
    13.Climbing distance5km (including return distance)
     
    14.Climbing speed15m/min~18m/min
     
    15.Pipeline curvaturemin 7D
     
    16.Single vehicle weight and dimensions(including no generator and battery)24kg, 1.18m×0.23m×0.16m
     
    17.Battery weight32.5kg
     
    18.X-ray generator weight and dimension16kg, Φ198mm×635mm  (XXH-2005)
     
    19.Magnetic locator weight and dimension2.8kg, 255 mm×113 mm×155 mm
     
    20.Magnetic locators penetration thickness≥34mm

Company Profile

  • Liaoning Ruiland Science & Technology Co., Ltd
  • [ China ]
  • This company is registered as a free member and is not verified or authenticated by Tradekey.com
  • Liaoning Ruiland Science & Technology Co., Ltd is formerly know as Dandong Radiative Instrument(Group) Co., Ltd which was established in 1956. Our company successfully developed the first industrial X-ray flaw detection apparatus in 1964.With unremitting efforts of several generations of our staffs, we have become national top-10 high-tech industrial manufacturers as well as being an enterprise...

Basic Information

  • Company Products / Services: industrial x ray machines, x ray equipment, portable x ray generator, x ray tube, diffraction analyzer, diffractometer, ut, ultrasonic detector, pipeline crawler
  • Year Established: 2012
  • Number of Employees: 26-50
  • Website: http://www.rstndt.com
Contact Now