Model | BE-96 | BE-72 | BE-48 |
Front frame | mm | 96*96 | 72*72 | 48*48 |
Panelcutout | mm | 91*91 | 68*68 | 45*45 |
AC current |
Ranges | mA | 50mA 100mA 150mA 200mA 400mA 500mA 600mA 800mA |
A | 1A 5A 10A 15A 20A 25A 30A 40A 50A 60A |
Combined with an external Current Transformer | X/1A | 10/1A 15/1A 20/1A 30/1A 40/1A 50/1A 60/1A 75/1A 100/1A 150/1A 200/1A 250/1A 300/1A 400/1A 500/1A 600/1A 800/1A 1000/1A 1200/1A 1500/1A 1600/1A 2000/1A 2500/1A 3000/1A More Ranges can be customized |
X/5A | 10/5A 15/5A 20/5A 30/5A 40/5A 50/5A 60/5A 75/5A 100/5A 150/5A 200/5A 250/5A 300/5A 400/5A 500/5A 600/5A 800/5A 1000/5A 1200/5A 1500/5A 1600/5A 2000/5A 2500/5A 3000/5A More Ranges can be customized |
The common type is with 2times overload, 1.0 1.5 2.0 3.0 5.0 6.0 times overload can be customized � |
AC voltage |
Ranges | v | 10V 25V 40V 60V 100V 150V 250V 300V 450V 500V 600V |
KV | Combined with an external PT **/100V **/110V **/120V |
Model | BE-96 | BE-72 | BE-48 |
Front frame | mm | 96*96 | 72*72 | 48*48 |
Panelcutout | mm | 91*91 | 68*68 | 45*45 |
AC Current with Recifier |
Ranges | mA | 50mA 100mA 150mA 200mA 400mA 500mA 600mA 800mA |
A | 1A 5A 10A 15A 20A 25A 30A |
Combined with an external Current Transformer | X/1A | 10/1A 15/1A 20/1A 30/1A 40/1A 50/1A 60/1A 75/1A 100/1A 150/1A 200/1A 250/1A 300/1A 400/1A 500/1A 600/1A 800/1A 1000/1A 1200/1A 1500/1A 1600/1A 2000/1A 2500/1A 3000/1A More Ranges can be customized |
X/5A | 10/5A 15/5A 20/5A 30/5A 40/5A 50/5A 60/5A 75/5A 100/5A 150/5A 200/5A 250/5A 300/5A 400/5A 500/5A 600/5A 800/5A 1000/5A 1200/5A 1500/5A 1600/5A 2000/5A 2500/5A 3000/5A More Ranges can be customized |
The common type is with 2times overload, 1.0 1.5 2.0 3.0 5.0 6.0 times overload can be customized � |
AC Voltmeter with Recifier |
Ranges | v | 10V 25V 40V 60V 100V 150V 250V 300V 450V 500V 600V |
KV | Combined with an external PT **/100V **/110V **/120V |
Model | BE-96 | BE-72 | BE-48 |
Front frame | mm | 96*96 | 72*72 | 48*48 |
Panelcutout | mm | 91*91 | 68*68 | 45*45 |
DC Current |
Ranges | uA | 50uA 100uA 150uA 250uA 800uA |
mA | 4-20mA 1mA 10mA 500mA 800mA |
A | 1A 2A 3A 4A 5A 10A 15A 20A 25A 30A 40A 50A |
For connecting to external shunt | 50mV 60mV 75mV | 10A 15A 20A 30A 40A 50A 60A 100A 150A 200A 250A 300A 400A 500A 600A 800A 1000A 1500A 2000A 2500A 3000A |
DC Voltmeter |
Ranges | v | 0.5V 1V 10V 25V 50V 100V 250V 500V 600V |
Maximun Demand Ammeter |
With bimetal movement and thermal delayed indicator for measuring the maximum mean load during a period of 8, 15 minutes, eats red maximum pointer. Scale compressed at the beginning, convenient reading from 25% OF full scale deflection. Accruacy of maximum load indication +-3% |
� | � | Model | Current | Response time / Real time |
Maximum Demand Indicator | � | BE-96 BE-72 | 1A or 5A | 8min 15min / 8min |
� | � | � | � | � |
Frequency Meters/Frequency Meter with Reeds |
Measuring frequency ranging from 45-65Hz , Moving Coil movement. The accuracy class is 2.5. Voltage Fluctuation Allowance:+-20% Frequency meters with one row of horizontal reeds are used to measure frequencies ranging from 45Hz to 65Hz. � |
Frequency Meter | � | Model | Measuring Rang | Voltage |
Pointer | � | BE-96 BE-72 BE-48 | 45-55Hz 45-65Hz 55-65Hz | 100V, 220V, 380V, 400V, 440V |
Vibrating | � | BE-96 BE-72 | 45-55Hz 47-53Hz | 100V, 220V, 380V, 440V |
� | � | � | � | � |
Power Factor Meters |
Analog panel meter composed of a core-magnet moving coil movement and a built in or a separate power factor converter. The power factor converter determines the cos phase angle between current and voltage. COS¢ is displayed at the moving coil movement. The symbol letters are PF. The accuracy class is 2.5 |
Power Factor Meter | � | Model | Specification | Voltage Current |
� | � | BE-96 BE-72 | 0.5lead-1.0-0.5lag | 110V 220V 380V 415V, 1A 5A |
� | � | � | � | � |
Power Meters for Active and Reactive Power |
Analog panel meter composed of a coremagnet moving coil movement and a built in or a separate power converter.Power meters are intended for measuring active and reactive power in single phase or three phase networks, with balanced or unbalanced load.The accuracy class is 1.5 |
� | � | Model | Voltage | Current |
Power Meter | � | BE-96 BE-72 | � | � |
Single phase system | � | � | 100V 220V | 1A 5A |
Three phase three wire 3P3W | � | � | 100V 220V 380V 440V | 1A 5A |
Three phase four wire 3P4W | � | � | 220(380V) 230(400V) 240(415V) | 1A 5A |