Isothermal Adsorption Analyzer

Zhejiang Finetec Instruments Co., Ltd

Product Description

  • Brand Name: FINETEC
  • Technique parameter
    Basic feature
    Single or multiple component isothermal adsorption and desorption
    Temperature: room temperature~ 100℃
    Operation pressure: 40MPa
    System maximum pressure: 70MPa
    Sample Cylinder, Reference Cylinder
     
    Sample Particle Size
    ≤60um
    Sample Weight
    200g
    Reference Cylinder Volume
    150ml
    Reference Cylinder Quantities
    6pcs OD: 70mm Length: 330mm
    Sampler Cylinder Volume
    150ml
    Material
    Stainless Steel
    Pressure Seal
    Specified Metal Ring Seal
    Stressor
    Gas Booster Pump
    Pressure Device
     
    Thermostat
     
    Oil Bath pan
    60L*2pcs
    Oil Bath pan Size
    50cm(length)*48cm(width)*24cm(depth)
    Temperature Setting
    Independent Zones
    Oil Bath pan Circulation
    Internal Installation
    Constant Temperature Oil
    BYOD
    Pressure Acquisition
     
    Pressure Sensor
    Three Wire Pressure Sensor
    Pressure Range
     0-40MPa
    Rated Pressure
    40MPa
    One-piece Barometer
    Precision±0.1%
    Quantity
    12pcs
    Output
     3mv/v
    Temperature Acquisition
     
    Temperature Detection System
    Temperature Sensor±0.1℃
    Multi-channel Digital Converter Precision
    16
    Gas source
     
    Aggregate Supply
    3
    Gas Input
    Methane, Helium, Carbon Dioxide
    Pressure
    20MPa
    Stability
    3%
    Electric Gas Regulator
     
    Aggregate Supply
    3
    Pressure
    40MPa
    Stability
    1%
    Input
     0-10v
    Booster Pressure
     0.6Mpa
    Computer Control
     
    Computer
    Basic Frequency0.3GHZ,
    Internal Storage1GB, Hard Disk 160GB
    Auto Control
    Computer
    System Software
     
    Other accessories (additional)
    Sample cylinder: 1
    Manual needle valve: 3
    Pneumatic valve: 2
    RTD: 2
    Headers: 6
    High pressure gas cylinder: different gas for 3 each
    Stainless iron pipe: 4
    Stable pressure power: 1
    Sealed circle: 4
     
    Isothermal Adsorption Process
    Industrial analysis implements complied with GB/T2121991
    Air Tightness Inspection
    Air inflation
    Filling Helium to system, pressure is higher than the highest pressure 1MPa of Isothermal Adsorption Experiment. System temperature adjusted to the reservoir temperature. Continuous observation for the system seal condition, if it’s good, to the next experiment.
    Free Space Volume Measurement
    Temperature
    System temperature is adjusted to reservoir temperature
    Inflation
    Open the cylinder; inflate the gas to system, adjust standard pressure valve, and then close the standard room valve
    Data Acquisition
    Open the valve of standard room and sample cylinder collect the data after the balance of pressure, do the volume experiment twice, allowable error is ±0.1cm3, calculate the coal volume and get the blank
    Isothermal Adsorption Experiment
    Experiment Pressure determination
    The highest experimental pressure is set up to 1.2 times of reservoir pressure, minimum pressure is 8MPa
    FINESORB-ISO Data Acquisition Software
    FINESORB-ISO Absorb/Desorb Data Processing Software
    Multicomponent Gas Absorb/Desorb Data Processing softer ware
    Chinese specification provided


     
    Air Compressor
     
     
    Inflation
    Open regulated valve and standard room valve, inflate methane to system, and adjust the standard room pressure to ideal pressure.
    Data acquisition
    After get the ideal pressure and stable temperature, start the data collection of the isothermal adsorption experiment program
    Time of Adsorption Balance Determination
    No less than 12 hours at least
    Repeating Step 3 -5, until the end of experiment of last pressure spot
     
    Data Processing
    The calculation of coal sample volume and free space volume
    The design formulas of coal volume as follows:
     
      
    VS- Coal sample volume, units of measurement (cm3);
    P1- Balanced pressure, units of measurement (MPa);
    P2- Initial pressure of reference cylinder, units of measurement (MPa);
    P3- Initial pressure of sample cylinder, units of measurement (MPa);
    T1- Balanced temperature, units of measurement (K);
    T2- Initial temperature of reference cylinder, units of measurement (K);
    T3- Initial temperature of sample cylinder units of measurement (K);
    V1- System total volume units of measurement (cm3);
    V2- Reference cylinder volume units of measurement (cm3);
    V3- Sample cylinder volume units of measurement (cm3);
    Z1- Gas compression factor under the balance condition, dimensionless
    Z2- Initial gas compression factor of reference cylinder, dimensionless
    Z3- Initial gas compression factor of sample cylinder, dimensionless
     
    After getting the coal sample volume, calculate the free space volume of sample cylinder. Free Space Volume refers to the sum of various volumes that coal particle space after the coal sample put into the sample cylinder, micro-flow gap of internal coal particle size, the remaining free space of sample cylinder, and connection tube and internal space volume. Calculation formulas of free space volume as follows:
    Vf- Free space volume, unit of measurement (cm3)
    V0- Total volume of sample cylinder, unit of measurement (cm3);
    Vs- Coal sample volume, unit of measurement (cm3);
    Z3- sample cylinder initial gas compressed factor, dimensionless
     
    Calculation the absorption capacity of each pressure spot
    According to balance pressure and temperature of reference cylinder and sample cylinder, calculate adsorption capacity of different pressure spot Formulas as follows
                               
    PV=nZRT
     
    P-Gas pressure, unit of measurement (MPa)
    V- Gas volume, unit of measurement (cm3);
    n- Gas mole number, unit of measurement (mol)
    Z- Gas compressor factor, dimensionless
    R- Molar gas constant, unit of measurement (U·mol-1·K-1)
    T- Thermodynamic temperature unit of measurement (K)
     
    Respectively obtain the gas mole number of inner sample cylinder before pressure spot balance and after balance, the gas mole number of sample cylinder (N2), mole number of coal sample adsorption of gas (ni)
    Ni=n1-n2
     
    ni- Gas mole number, unit of measurement (mol)
    N1- Sample cylinder‘s gas mole quantity after balance, unit of measurement (mol).
    N2- Sample cylinder‘s gas mole quantity after balance, , unit of measurement (mol).
    Adsorption gas volume of each pressure spot
    VI=ni * 22.4 * 1000
     
    The gas volume of each pressure spot adsorption:
     
    V adsorption=V i/ c
    V-adsorption- Adsorption capacity, unit of measurement (cm3/g)
    -total volume of adsorption gas, unit of measurement (cm3/g)
    -coal sample weight, unit of measurement (g)
    Data Calculation and Report
    Adsorption Isotherm
    According to adsorption capacity of each balance pressure V and pressure F drew the adsorption isotherm.
    Experiment Precision
    5.1 Repeatability
    VL repeatability of relative error less than 15%
    PL repeatability of relative error less than 15%
    5.2 Reproducibility
    VL reproducibility of relative error less than 20%
    PL reproducibility of relative error less than 20%
    5.3 Sample experimental weight
    Related coefficient R of P/V and P is greater than 0.98
    Sample experimental quality
    P/V and its relative coefficient R >0.98
     
     

Company Profile

  • zhejiang Finetec Instruments Co., Ltd
  • [ China ]
  • This company is registered as a free member and is not verified or authenticated by Tradekey.com
  • COMPANY PROFILE The FINETEC INSTRUMENT COMPANY located in the Zhejiang province China 2012 High end micro pore surface and porosity analyzer approved by the market Pilot plant test laboratory is approved in the catalyst and chemical synthesis area The analyzer CBM and shale gas fill the domestic blank High end experimental furnace, vacuum oven and multidigit sample valve are launched. ...

Basic Information

  • Company Products / Services: instruments gas chromatograph chemical analyzer
  • Year Established: 2007
  • Number of Employees: 26-50
  • Website: www.finetec.info
Contact Now