Type | Y type, T type, detachable, double tubesheet, cold trap, gas-liquid separation etc. |
Material | austenitic stainless steel 316L, double-phase stainless steel 2205, 2507, pure titanium, zirconium, Hastelloy alloy, etc. |
Tube type | Spiral wound tube/parallel tube/U type tube |
Tube | Φ8,Φ10,Φ12, Φ14,Φ16, Φ19,Φ25etc. |
media | steam-steam, steam-liquid, liquid-steam and liquid-liquid |
Applicable fluids | steam, circulating water, frozen brine, glacial refrigerant, glycol; |
Maximum working pressure | 4Mpa |
Heat exchanger area | 0.1-1000 square meters |
working temperature | -20-300 degree celsius (customizable) |
installation type | Horizontal/Vertical |
function | Heater, cooler, condenser, evaporate, distillation, rectification |
Application:Distillation reflux system, concentration system, distillation system, waste gas and heat recovery system, traditional Chinese medicine extraction system, instantaneous sterilization at high temperature, CIP cleaning system, civil HVAC system, heating and cooling of process materials
Customization:According to the technical requirements of customers, we can accurately customize the winding tube heat exchangers with various spacing.
Package:Standard export wooden box, can be packaged according to customer requirements.
Advantages: 1.
High heat transfer coefficient The unique spiral wound tube bundle optimizes the flow state of the fluid on both sides, and the heat exchange capacity per unit area is 3-5 times that of the traditional heat exchange area.
It can be used as a heater to improve the heat utilization rate, and when used as a condenser, it can improve the material recovery rate and save the cost of refrigerant.
2.
Long service life The elastic tube bundle in the heat exchanger can effectively absorb stress and vibration, prolong the service life of the heat exchanger, and the design life is up to 20 years.
3.
Low scaling tendency Unique Y-shaped interface, there is no dead angle in the heat exchanger, and the tube side and shell side can be emptied; the high flow rate design of the shell side can effectively reduce the probability of scaling on the surface of the heat exchange tube, and the scaling tendency is low.
4.
small floor space The structure is compact. Under the same working conditions, the volume is only about 1/5 of the traditional heat exchanger, which saves space and reduces the load.
5.
Low operating cost Under the steam heating condition, the steam is saved more than 10%. Under the condensing condition, the recovery rate is increased by 1-3%, and the condensing temperature is lower under the same refrigerant; the same condensing temperature reduces the consumption of low-temperature refrigerant and saves operating costs.