Gf312v2 Portable Three Phase Multifunction Watt-hour Meter Calibrator

Beijing GFUVE Electronics Co., Ltd

Product Description

  • Brand Name: GFUVE
  • Measuring Energy Range: 1mA-12A & 1mA-120A
  • Accuracy Class: 0.05%
  • Output Voltage: 0-600V
  • Operating Temperature: -25°C to +50°C
  • Dimensions: 245×168×70
  • GF312V2PORTABLE THREE PHASE MULTIFUNCTION WATT-HOUR METER CALIBRATOR

    GF312V2 portable three phase multifunction watt-hour meter calibrator on-site is the newest product produced by our company by widely visiting users and referring to the advantages of the same kind of products home and abroad. The measured part of the product adopts high speed A/D transmission to send DSP to conduct digital processing, which largely improves measured degree of accuracy and stability. Central processing part adopts 32-bit ARM embedded technology to make instrument interface novel, function abundant, operation distinct and easy, and performance steady. Class of accuracy: Class 0.02, 0.05 or 0.1, range from 12A/600V or 120A/600V, with comfort design, small size and light weight. The model GF312V2 watt-hour meter calibrator is suit for electric power departments, measuring and quality examining departments and electric lab to field use. PARAMETERS Electrical parameters Voltage measurement Current measurement Power measure error Energy measure error Phase angle Frequency Reference Meter Pulse output Pulse input Display Function Safety Mechanical parameters Environmental conditions
    Accuracy class 0.02%, 0.05%, 0.1%
    Power Supply External power, 85-265V, 45-65Hz
    Phase voltage supply 40-450V, 45-65Hz
    Li-Battery supply
    Range 0-600V
    Error ±0.05%(30-600V); ±0.02%(30-600V)
    Harmonic 2nd-51st
    Input impedance range 245kΩ@ 250V; 10MΩ @5V
    Stability 0.01%/minute
    Long term stability < 100× 10E -6 /Year
    Range (direct connection) 1mA-12A or 1mA-120A
    Range (clamp CT) 1mA-120A
    Clamp on CTs Optional 5A, 20A, 100A, 200A, 500A, 1000A, 2000A, 3000A
    Error (direct connection) ±0.05% or ±0.02%
    Error (clamp CT) ±0.2% (1mA-120A )
    ±0.5% (other)
    Harmonic 2nd-51st
    Clamp diameter 12mm or 18mm
    Input impedance range 0.04Ω@ 0.05A-12A
    Stability 0.01%/minute
    Long term stability < 100× 10E -6 /Year
    Active power (direct connection) ±0.05% or ±0.02%
    Active power (clamp CT) ±0.2% (1mA-120A)
    Reactive power (direct connection) ±0.1% or ±0.05%
    Reactive power (clamp CT) ±0.2% (1mA-120A)
    Stability 0.01%/minute
    Long term stability < 100× 10E -6 /Year
    Active energy (direct connection) ±0.05% or ±0.02%
    Active energy (clamp CT) ±0.2% (1mA-120A)
    Reactive energy (direct connection) ±0.1% or ±0.05%
    Reactive energy (clamp CT) ±0.2% (5mA-120A)
    Stability 0.01%/minute
    Long term stability < 100× 10E -6 /Year
    Range 0°-360°
    Resolution 0.001°
    Error ±0.015°
    Range 15Hz-70Hz
    Resolution 0.0005Hz
    Error 0.001Hz
    Measuring modes 2WA / 2WR / 2WAP3WA / 3WR /3WAP /3WRCA /3WRCB4WA /4WAb / 4WR /4WRb /4WAP /4WAPb /4WRC
    Brandwidth 3000Hz
    Sampling 16 bit 504 samplers/ period
    Energy constant 25000
    Pulse ratio 1:1
    Output level 5V
    Input channel 2
    Input level 5-10V
    Input frequency Max. 100Hz
    Resolution 800×480
    LCD 7" TFT color touch
    Vector diagram Yes
    Waveform Yes
    Energy accumulation Yes
    CT ratio test Yes
    CT PT programmable Yes
    Local parameter input Yes
    Wiring emulation Yes
    Self-calibration Yes
    Recorder check Yes
    Data storage Yes
    GPS Yes
    Data storage qty 10000
    External extend memory Yes
    Screen printing Yes
    Communication port USB/RS232 
    Communication with PC Yes
    Upload data Yes
    External mini printer Yes
    External keyboard Yes
    IP class according to DIN EN 60529 IP42
    Declaration of conformity CE & CNAS conform
    Protection class according to DIN EN 61140 II
    Overvoltage category voltage measurement CAT III 600V
    Overvoltage category current CAT III 600V
    Dimensions (W×H×D) (mm) 245×168×70
    Weight (kg) 1.8
    Ambient temperature -25°C to +50°C
    Storage temperature -30°C to +65°C
    Relative humidity 30%-95%
    Power Consumstion ≤13VA

     

Company Profile

  • Beijing GFUVE Electronics Co., Ltd
  • [ China ]
  • This company is registered as a free member and is not verified or authenticated by Tradekey.com
  • Beijing GFUVE Electronics Co., Ltd. was established in 2005. It combined science, industry and trade together as one high-tech enterprise. GFUVE mainly produces high voltage ammeter recorder, IEC61850 test suite software, meter test equipment, reference standard meter, phantom load power source, electrical measurement instrument, relay test set, transformer test, handheld terminal and POS termi...

Basic Information

  • Company Products / Services: pos terminal, meter test equipment, reference standard meter, high voltage ammeter, handheld terminal, pda, power sources, transformer test equipment, transducer, power meter
  • Year Established: 2005
  • Number of Employees: 51-100
  • Website: www.gfuvegroup.com