Forged super alloy steel -Quenched and Tempered
Individually proof test at 2.5 times Working Load Limit
Fatigue tested at 1.5 times Working Load Limit for20000 cycles
Breakage test
100% magnaflux crack detection
Item No. |
Weight/kg |
WLL/T |
B.L/T |
A±0.5 |
B±1 |
E±1 |
H±1 |
R±2 |
M±2 |
L±3 |
8-DS766-06 |
0.5 |
1.12 |
4.48 |
7.5 |
32 |
28 |
20 |
96 |
70 |
131 |
8-DS766-08 |
0.9 |
2 |
8 |
9.5 |
36 |
35.5 |
26 |
123 |
90 |
166 |
8-DS766-10 |
1.6 |
3.15 |
12.6 |
12 |
46 |
45 |
30 |
144 |
109 |
196.5 |
8-DS766-13 |
2.9 |
5.3
|
21.2 |
15 |
59 |
53.5 |
40.5 |
182 |
138.5 |
251 |
8-DS766-16 |
5.9 |
8 |
32 |
17.5 |
70 |
62 |
50.5 |
217 |
170.5 |
|